Application : Railway monitoring system
Industry: Railway power supply automation system and urban rail transit integration service
The railway power supply comprehensive system uses remote communication technology to transmit information to achieve remote monitoring and control of on -site equipment. Its system composition mainly includes: dispatching center system, accusing station system, communication channels, and re -display equipment.
The subsystem of the railway power supply comprehensive system includes: dispatch center system, contact network switch monitoring system, high -voltage electrical equipment comprehensive online monitoring system, comprehensive automation system for power distribution, power supply environmental safety monitoring system, and power remote measurement and control terminal.
Customer requirements: 10.1 inch LCD screen EDP interface
Our solutions: G101UAN01.0 AUO 10.1 -inch industrial LCD screen
The resolution of G101UAN01.0 is 1920 (RGB) × 1200wuxga 224ppi, and the brightness is 380 cd/m² (TYP.), contrast ratio: 800: 1, visual angle: 89/89/89/89 (TYP.) (CR ≥ 10), Work temperature: -10 ~ 60 ° C, signal system 30 pins EDP (2 LANES), EDP1.2, terminal, backlight type WLED, 30K hours, LED drive, response speed 25 (TYP.) (TR+TD) MS , G101UAN01.0 is suitable for industry.
Advantages and disadvantages: The output of the customer's motherboard is EDP, and the LCD screen must have wide temperature. G101UAN01.0 is AUO's 10.1 high -resolution industrial LCD screen. It has 30K hours and is applied to industry and military which have high requirements for resolution.